We are Importer, Supplier & Seller of Scientific Instrument, Medical Equipment, Laboratory Chemical, Glassware, Pharmaceutical Raw, Q.C Material.

Multi-Parameter (Water Quality Meter) – YK-2005WA

Brand: Lutron
Model: YK-2005WA
Origin: Taiwan

The YK-2005WA Multi-Parameter Water Quality Meter offers accurate and reliable measurements for various parameters, making it an essential tool for applications in water conditioning, aquariums, food processing, and more.

Exceptional Features of the YK-2005WA:

1. Multi-Parameter Measurement: Measures pH, ORP, conductivity (CD), TDS, and dissolved oxygen (DO), providing comprehensive testing capabilities.
2. Real-Time Data Logger: Features a real-time data logger with a built-in clock and calendar, allowing for real-time data recording with adjustable sampling times from 1 second to 8 hours, 59 minutes, and 59 seconds.
3. Automatic and Manual Temperature Compensation: Offers both automatic and manual temperature compensation options, ensuring accurate readings under varying conditions.
4. Auto Calibration: Supports auto calibration for pH 4, pH 7, and pH 10, ensuring precise measurements.
5. RS232/USB Interface: Equipped with RS232 and USB interfaces for easy data transfer to a computer, facilitating further analysis and record-keeping.

Specifications

Display: LCD size: 58 mm x 34 mm.
Measurement: PH/ORP
Measurement: Conductivity/TDS (Total Dissolved Solids)
Measurement: Dissolved Oxygen
Resolution: /
Accuracy: /
Temperature Compensation: /
Probe Structure: /
Data Hold: Freeze the display reading.
Memory Recall: Maximum & Minimum value.
Sampling Time: Approx. 1 second.
Circuit: Custom one-chip of microprocessor LSI circuit.
Power off: Auto shut off saves battery life or manual off by push Button.
Power off: Can default auto power or manual power off.
Power off: When default auto power function, power will off automatically after 10 MIN, if no Button be pressed.
Operating Temp.: 0 to 50°C. – Main instrument.
Operating Humidity: Less than 80% R.H.
Power Supply: DC 1,5 V battery (UM3) x 4 PCs, (Heavy duty type).
Power Supply: DC 9V adapter input. @ AC/DC power adapter is optional.
Power Consumption: /
Dimension: 203 x 76 x 38 mm
Weight: 365 g/ 0.8 LB. @ Battery is included.
Datalogger Sampling Time Setting range: 2 sec to 8 hour 59 min. 59 sec.
Datalogger Sampling Time Setting range: @ Auto datalogger
Memory Card: /
Advanced setting: /
Power Current: Operation: Approx. DC 28 mA
Power Current: Clock (power off): Approx. DC 1 uA.
Data Output: RS 232 PC serial interface.
Standard Accessories: /
Optional Accessories: PH electrode: PE-03, PE-11, PE-01, PE06HD PE-04HD, PE-05T, PE-03K7
Optional Accessories: ATC (Automatic Temperature Probe): TP-07
Optional Accessories: pH 7 buffer solution: PH-07
Optional Accessories: pH 4 buffer solution: PH-04
Optional Accessories: Conductivity probe: CDPB-03
Optional Accessories: 1.413 mS Conductivity Standard Solution: CD-14
Optional Accessories: Oxygen probe: OXPB-11
Optional Accessories: Spare Probe head with Diaphragm set: OXHD-04
Optional Accessories: Probe-filling Electrolyte: OXEL-03
Optional Accessories: AC to DC 9V adapter.
Optional Accessories: RS232 cable, UPCB-02.
Optional Accessories: USB cable, USB-01
Optional Accessories: Data Acquisition software, SW-U801-WIN.
Optional Accessories: Data Logger software, SW-DL2005.

Technical Specifications:

Measurement Ranges:
pH: 0 to 14.00 pH
ORP: ± 1999 mV
Conductivity: 0 to 200 µS, 0.2 to 2.000 mS, 2 to 20.00 mS, 20 to 200.0 mS
TDS: 0 to 132 PPM, 132 to 1,320 PPM, 1,320 to 13,200 PPM, 13,200 to 132,000 PPM
Dissolved Oxygen: 0 to 20.0 mg/L
Temperature: 0 to 50℃
Resolutions:
pH: 0.01 pH
ORP: 1 mV
Conductivity: 0.1 µS, 0.001 mS, 0.01 mS, 0.1 mS
TDS: 0.1 PPM, 1 PPM, 10 PPM, 100 PPM
Dissolved Oxygen: 0.1 mg/L
Temperature: 0.1℃ / 0.1℉
Accuracy:
pH: ±0.02 pH + 2d
ORP: ±0.5% + 2d
Conductivity: ±2% F.S. + 1d
TDS: ±2% F.S. + 1d
Dissolved Oxygen: ±0.4 mg/L
Temperature: ±0.8℃ / ±1.5℉
Display: Jumbo LCD display
Power Supply: DC 1.5V battery (UM-3, AA) x 4 PCs or DC 9V adapter
Dimensions: 203 x 76 x 38 mm
Weight: 365 g

Included Accessories:

Instruction manual
pH electrode (PE-03)
Conductivity/TDS probe (CDPB-03)
Dissolved oxygen probe (OXPB-11)
pH 7.00 buffer solution (PH-07)
pH 4.00 buffer solution (PH-04)
Hard carrying case (CA-06)

Optional Accessories:

ORP electrode (ORP-14)
ATC temperature probe (TP-07)
Spare probe head with diaphragm set (OXHD-04)
Probe-filling electrolyte (OXEL-03)
Conductivity standard solution (CD-14)
RS232 cable (UPCB-02)
USB cable (USB-01)
Data acquisition software (SW-U801-WIN)
Data logger software (SW-DL2005)

Versatile Applications:

Ideal for use in aquariums, beverage industry, fish hatcheries, food processing, photography, laboratories, paper industry, plating industry, quality control, schools, colleges, and water conditioning.

Invest in the YK-2005WA Multi-Parameter Water Quality Meter for reliable, precise measurements and a robust design that meets the diverse needs of various industries with precision and ease.

Reviews

There are no reviews yet.

Be the first to review “Multi-Parameter (Water Quality Meter) – YK-2005WA”

Your email address will not be published. Required fields are marked *

Category: