The WAC-2019SD Multi-Parameter Water Quality Meter offers accurate and reliable measurements for various parameters, making it an essential tool for applications in water conditioning, aquariums, food processing, and more.
Exceptional Features of the WAC-2019SD:
1. Multi-Parameter Measurement: Measures pH, ORP, conductivity (CD), TDS, salt, and dissolved oxygen (DO), providing comprehensive testing capabilities.
2. Real-Time Data Logger: Features an SD card real-time data logger with a built-in clock and calendar, allowing for real-time data recording with adjustable sampling times from 1 second to 8 hours, 59 minutes, and 59 seconds.
3. Automatic and Manual Temperature Compensation: Offers both automatic and manual temperature compensation options, ensuring accurate readings under varying conditions.
4. Auto Calibration: Supports auto calibration for pH 4, pH 7, and pH 10, ensuring precise measurements.
5. RS232/USB Interface: Equipped with RS232 and USB interfaces for easy data transfer to a computer, facilitating further analysis and record-keeping.
Specifications
Display: TFT LCD size: 2.4″
Measurement: PH/ORP
Measurement: Conductivity/TDS (Total Dissolved Solids)
Measurement: Dissolved Oxygen
Measurement: Salt
Resolution: /
Accuracy: /
Temperature Compensation: /
Probe Structure: /
Data Hold: Freeze the display reading.
Memory Recall: Maximum & Minimum value.
Sampling Time: Approx. 1 second.
Circuit: Custom one-chip of microprocessor LSI circuit.
Power off: /
Operating Temp.: 0 to 50°C.
Operating Humidity: Less than 85% R.H.
Power Supply: Alkaline or heavy duty DC 9 V (006 P) battery or equivalent.
Power Supply: DC 9V adapter input. (AC/DC power adapter is optional).
Power Consumption: /
Dimension: 180 x 77 x 45 mm (11.5 x 8.7x 3.6 inch)
Weight: 489 g/1.08 LB.
Datalogger Sampling Time Setting range: /
Memory Card: /
Advanced setting: Auto power OFF management
Advanced setting: Set beep Sound ON/OFF
Advanced setting: Set temperature unit to °C or °F
Advanced setting: Set DO salt% compensation value
Advanced setting: Set DO height (meter) compensation value
Advanced setting: Set DO height (feet) compensation value
Advanced setting: Set CD temperature compensation factor
Advanced setting: Set CD to TDS or TDS to CD, CD only
Advanced setting: Set pH manual Temp. compensation value
Power Current: Normal operation (LCD Backlight is OFF) :
Power Current: Approx. DC 14 mA.
Data Output: RS 232/USB PC computer interface.
Data Output: Connect the optional RS232 cable UPCB-02 will get the RS232 plug.
Data Output: Connect the optional USB cable USB-01 will get the USB plug.
Standard Accessories: /
Optional Accessories: PH electrode: PE-03, PE-11, PE-01, PE06HDA PE-04HD, PE-03K7
Optional Accessories: ATC probe (Automatic Temperature Probe): TP-07
Optional Accessories: pH 7 buffer solution: PH-07
Optional Accessories: pH 4 buffer solution: PH-04
Optional Accessories: Conductivity/TDS probe, Salt probe: CDPB-03
Optional Accessories: 1.413 mS Conductivity Standard Solution: CD-14
Optional Accessories: Oxygen probe: OXPB-11
Optional Accessories: Spare Probe head with Diaphragm set: OXHD-04
Optional Accessories: Probe-filling Electrolyte: OXEL-03
Optional Accessories: ORP Electrode: ORP-14
Optional Accessories: SD memory card (4 GB)
Optional Accessories: AC to DC 9V adapter.
Optional Accessories: USB cable, USB-01.
Optional Accessories: RS232 cable, UPCB-02.
Optional Accessories: Data Acquisition software,SW-U801-WIN.
Technical Specifications:
Measurement Ranges:
pH: 0 to 14.00 pH
ORP: ± 1999 mV
Conductivity: 0 to 200 µS, 0.2 to 2.000 mS, 2 to 20.00 mS, 20 to 200.0 mS
TDS: 0 to 132 PPM, 132 to 1,320 PPM, 1,320 to 13,200 PPM, 13,200 to 132,000 PPM
Salt: 0 to 12 % salt (by weight)
Dissolved Oxygen: 0 to 20.0 mg/L
Temperature: 0 to 60℃
Resolutions:
pH: 0.01 pH
ORP: 1 mV
Conductivity: 0.1 µS, 0.001 mS, 0.01 mS, 0.1 mS
TDS: 0.1 PPM, 1 PPM, 10 PPM, 100 PPM
Salt: 0.01 % salt
Dissolved Oxygen: 0.1 mg/L
Temperature: 0.1℃ / 0.1℉
Accuracy:
pH: ±0.02 pH + 2d
ORP: ±0.5% + 2d
Conductivity: ±2% F.S. + 1d
TDS: ±2% F.S. + 1d
Salt: ±0.5 % salt value
Dissolved Oxygen: ±0.4 mg/L
Temperature: ±0.8℃ / ±1.5℉
Data Logger:
Auto Data Logger: 1 second to 8 hours, 59 minutes, 59 seconds
Manual Data Logger: Set sampling time to 0 second
Memory Capacity: 1 GB to 16 GB SD card
Display: 2.4″ TFT LCD with green backlight, easy reading
Power Supply: DC 9V battery (006P) or DC 9V adapter
Dimensions: 180 x 77 x 45 mm (7.1 x 3.0 x 1.8 inches)
Weight: 489 g (1.08 lb)
Included Accessories:
Instruction manual
pH electrode (PE-03)
Conductivity/TDS probe (CDPB-03)
Dissolved oxygen probe (OXPB-11)
pH 7.00 buffer solution (PH-07)
pH 4.00 buffer solution (PH-04)
RS232 cable (UPCB-02)
USB cable (USB-01)
Data acquisition software (SW-U801-WIN)
Data logger software (SW-DL2005)
Hard carrying case (CA-06)
Optional Accessories:
ORP electrode (ORP-14)
ATC temperature probe (TP-07)
Spare probe head with diaphragm set (OXHD-04)
Probe-filling electrolyte (OXEL-03)
Conductivity standard solution (CD-14)
Versatile Applications:
Ideal for use in aquariums, beverage industry, fish hatcheries, food processing, photography, laboratories, paper industry, plating industry, quality control, schools, colleges, and water conditioning.
Invest in the WAC-2019SD Multi-Parameter Water Quality Meter for reliable, precise measurements and a robust design that meets the diverse needs of various industries with precision and ease.
Reviews
There are no reviews yet.